振動時效消除殘余應力檢測結果 焊縫殘余應力檢測數據
單位:MPa
點號 |
振前 σ1 |
振后 σ1 |
變化率 % |
振前 σ2 |
振后 σ2 |
變化率 % |
振前 θ(度) |
振后 θ(度) |
1 |
216.67 |
135.06 |
37.7 |
180.13 |
105.59 |
41.4 |
27.38 |
16.03 |
2 |
332.48 |
152.30 |
54.2 |
196.51 |
130.28 |
33.7 |
14.29 |
2.14 |
3 |
351.68 |
159.99 |
54.5 |
217.51 |
136..38 |
37.3 |
13.31 |
-0.67 |
4 |
199.10 |
122.42 |
38.5 |
141.49 |
110.77 |
21.7 |
12.24 |
-4.07 |
5 |
400.80 |
161.96 |
59.6 |
266.03 |
141.88 |
46.7 |
23.49 |
1.96 |
6 |
211.90 |
128.47 |
39.4 |
162.00 |
112.77 |
30.4 |
42.32 |
-18.23 |
7 |
374.82 |
164.34 |
56.2 |
245.49 |
136.05 |
44.6 |
23.45 |
-0.83 |
8 |
228.91 |
159.33 |
30.4 |
180.04 |
134.75 |
25.2 |
-0.64 |
14.71 |
9 |
205.63 |
139.01 |
32.4 |
147.60 |
113.14 |
23.3 |
26.54 |
9.60 |
10 |
385.38 |
165.49 |
57.1 |
222.87 |
128.01 |
42.6 |
19.28 |
-14.69 |
11 |
232.78 |
147.79 |
36.5 |
182.49 |
113.54 |
37.8 |
-1.41 |
-13.59 |
12 |
407.51 |
166.64 |
59.1 |
309.87 |
156.72 |
49.4 |
1.85 |
7.21 |
13 |
357.42 |
161.97 |
54.7 |
234.75 |
136.70 |
41.8 |
22.23 |
-1.24 |
14 |
358.44 |
157.31 |
56.1 |
249.80 |
134.46 |
46.2 |
26.61 |
12.05 |
15 |
211.62 |
129.80 |
38.7 |
156.54 |
117.75 |
24.8 |
15.78 |
5.91 |
16 |
296.95 |
155.27 |
47.7 |
211.93 |
126.17 |
40.5 |
29.23 |
17.89 |
17 |
373.53 |
158.82 |
57.5 |
232.99 |
128.36 |
44.9 |
26.23 |
16.99 |
18 |
214.16 |
151.90 |
29.1 |
149.98 |
120.34 |
19.8 |
37.57 |
24.97 |
平均應力 |
297.77 |
150.99 |
49.3 |
204.89 |
126.87 |
38.1 |
/ |
/ |
19 |
80.27 |
73.16 |
8.9 |
21.82 |
36.37 |
-66.6 |
11.79 |
6.70 |
. 注:熱影響區檢測點排序分別為4、6、11、16點
結論與分析:①從A線振動處理時給出了2條的監測曲線可以看出本次振動時效處理達到了效果;
②從表1檢測數據可以看出焊接件振動處理前主應力為297.77MPa,而振動處理后主應力為150.99MPa,平均消除率為49.3%,最高點消除59.6%符合要求。這次VSR處理合格。
附件
測試數據
一、數據編輯序號相對構件點位對照
數據序號: 相對構件測試點位置編號
*************************
1: A/D1
2: A/D3
3: A/D5
4: A/D5(影響區)
5: AB7
6: A/B9(影響區)
7: A/B9
8: A/B11
9: A/E1
10: A/E3
11: A/E4(影響區)
12: A/E5
13: A/C7
14: A/C9
15: A/C11
16: A/C10(影響區)
17: A6
18: 12
***********************
19: A母材